Internal Error 2753 During Install
This article applies to:
- Kurzweil 1000
- Kurzweil 3000 for Windows
Symptoms
During the installation, a dialog appears with the caption "Internal
Error 2753. KESIPrntInstall.exe".
Cause
This problem occurs when an older Kurzweil application is installed
on a system that has a newer Kurzweil application already installed. For
example, version 7 of the Kurzweil 3000 for Windows was released in
January, 2003. Version 7 or the Kurzweil 1000 was released in August,
2002, so it is older. If Kurzweil 3000 version 7 is installed on a
system, then Kurzweil 1000 version 7 is installed on the same system,
this error will occur.
Solution
When multiple Kurzweil Educational Systems applications are
installed on a system, it is critically important that they be installed
in the order the applications were released by Kurzweil Educational
Systems. Each CD has a date printed on it. If a newer Kurzweil product
is already on the system, the safest course of action is to uninstall
that product, then install the older product, followed by the newer
product.
Uninstalling a Kurzweil application will not delete your settings or
documents, so uninstalling and reinstalling will not cause any harm.
A more direct solution to the Internal Error 2753 is to use Windows
Explorer to go to Kurweil's common files directory (usually C:\Program
Files\Kurzweil Educational Systems\Common Files), delete the
KESIPrntInstall.exe and Router.exe programs, then re-install the
application whose installation had failed. This avoids the Error 2753,
but is not recommended, since installing an older application over a
newer application can cause other problems later that will seem
mysterious and hard to fix.
History
Creation Date: March 5, 2003
Last Modified: March 5, 2003
|